Side Mounted ON/OFF Function PIR Sensor for 3m - 6m Max Mounting Height
Place of Origin | Shenzhen, China |
---|---|
Brand Name | Merrytek |
Certification | CE, RED |
Model Number | MC168S IR |
Minimum Order Quantity | 100PCS |
Price | Negotiable |
Packaging Details | Bubble bag + cardboard + outer carton(K=A) |
Delivery Time | 1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit. |
Payment Terms | T/T |
Supply Ability | 10000 pcs/month |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xOperating Voltage | 220-240Vac | Stand-by Power | ≤0.5W |
---|---|---|---|
Mounting Height | 3m (6m Max) | Operating Temperature | -20℃~+55℃ |
Certificates | CE, RED | Lifetime | 3 Years Warranty@Ta 230Vac Full Load |
Highlight | Side Mounted PIR Sensor,ON/OFF Function PIR Sensor,3m - 6m PIR Sensor |
【Product Feature】
- Designed for LED fixtures, side mounted ON/OFF function PIR sensor.
- Easily programming detection area, hold time and daylight threshold by the rotary switch
- Max mounting height 6 m
【Parameters】
Input | |
Operating Voltage | 220-240Vac |
Rated Voltage | 230Vac |
Stand-by Power | ≤0.5W |
Surge Test | 1KV(L/N, EN61000-4-5) |
Output | |
Working Mode | ON/OFF |
Load Type | Inductive Load/Resistive Load |
Load Power | 200W@230VAC(Inductive Load),400W @230VAC(Resistive Load). |
Load Surge Current | 30A (50% Ipeak, Twidth 200us @230Vac full load, cold start) |
Sensor Parameters | |
Detection Way | PIR |
Hold Time | 5s/30s/1min/5min by rotary switch |
Detection Area | 100%/75%/50%/25% by rotary switch |
Daylight Sensor | 10Lux/30Lux//50Lux/Disable (Diffusion) by rotary switch |
Detection Range(Radius) |
Ceiling Mounting at 3m high, r≥3m@0.6~1m/s tangential direction Wall mounting at 1.2m high, r≥6m@0.6~1m/s tangential direction |
Test condition: 100% sensitivity, indoors, no direct sunlight to sensor, no wind, Temperature 25℃ |
|
Mounting Height | 3m (6m Max) |
Environment | |
Operating Temperature | -20℃~+55℃ |
Storage Temperature | -40℃~+80℃, humidity≤85%(Non-condensing) |
Certificate Standards | |
Safety (LVD) standard | EN61058-1-2, EN61058-1 |
Surge | 1KV(L/N, EN61000-4-5) |
EMC Standards | EN55015 |
Environmental Requirement | Compliant to RoHS 2.0, Reach |
Certificates | CE, RED |
IP Rating | IP65 |
Product classification | Class II |
Others | |
Wiring | Lead wire, wire diameter: 0.75mm2 |
Installation | External side mounting |
Package | Bubble bag + cardboard + outer carton(K=A) |
Net Weight | 67.5±3g |
Lifetime | 3 years warranty@Ta 230Vac full load |
【Product Information】
- Dimension(units:mm)
- Wiring
- Function
【Installation Instruction】
【Detection Range】
【Rotary Switch Function】
【Initialization】
After power on, the sensor automatically turns on light to 100% brightness and turns off light in 45±5 seconds. During initialization, sensor is not able to detect movement.
【Factory Setting】
Sensitivity: 100% Hold-time: 5s Daylight sensor: Disable
【Application Notice】
- Sensor should be installed by a professional electrician. Please turn off power before installing, wiring.
- The typical installation height is 3m. It’s for indoor use only, in order to avoid false trigger by the ambient temperature. Pls do not install in locations sensitive to temperature or airflow changes, to avoid sensing failure due to false trigger or high temperature.
- Sensors should be kept away from air conditioners, refrigerators, exhaust vents, furnaces, and other places sensitive to changes in air temperature.
- Sensors should not be obstructed by screens, furniture, large bonsai or other isolating objects within the detection range.
- Reflective objects should be avoided directly in front of the sensor, reflecting light will cause the sensor to be triggered incorrectly.
- Sensors should not be installed indoors directly in front of a window, otherwise the disturbance of thermal airflow outside the window and the movement of people will cause false alarms. The sensitivity of PIR sensors to the human body is also highly related to the direction of human movement, radial movement is at the least sensitivity, while highly sensitive to the cross section direction (perpendicular to the radius).
- The distance detect standards: At night, indoor ambient temperature of 25℃, humidity 50-70%, the human body surface temperature of 36-37 degrees, people walk in the cross-section direction at the speed of 0.6 ~ 1m / s. The maximum sensing angle of the product is based on highest sensitivity setting, if set at low sensitivity can not fulfil the maximum sensing angle. The sensing distance is related to the height of the tester, the installation height and working environment etc.
- As PIR sensor probe is relatively fragile, pls pay attention to protection during production, storage, handling, transportation, consumer installation, and need to be gently held and put under no effective protective packaging. If the product falls may cause the infrared probe to appear hidden cracks or damage to the inner chip, then it will not work or false trigger.